[[File:Dampfturbine Laeufer01.jpg|thumb|The rotor of a modern steam turbine used in a [[power plant]]]]
Marvella is what you can contact her but it's not the most feminine title out there. She is a librarian but she's always needed her personal company. His wife doesn't like it the way he does but what he really likes performing is to do aerobics and he's been performing it for fairly a while. Her family life in Minnesota.<br><br>My homepage [http://narehh.wannamoskva.com/members/kristbrunton/activity/61026/ std testing at home]
A '''steam [[turbine]]''' is a device that extracts [[thermal energy]] from pressurized [[steam]] and uses it to do [[Work (physics)|mechanical work]] on a rotating output shaft. Its modern manifestation was invented by [[Charles Algernon Parsons|Sir Charles Parsons]] in 1884.<ref>{{cite web|author=Encyclopædia Britannica |url=http://www.britannica.com/EBchecked/topic/444719/Sir-Charles-Algernon-Parsons |title=Sir Charles Algernon Parsons (British engineer) - Britannica Online Encyclopedia |publisher=Britannica.com |date=1931-02-11 |accessdate=2010-09-12}}</ref>
 
Because the turbine generates [[rotational motion|rotary motion]], it is particularly suited to be used to drive an [[Electric generator|electrical generator]]&nbsp;– about 90% of all electricity generation in the United States (1996) is by use of steam turbines.<ref Name="Wiser">{{cite book |title=Energy resources: occurrence, production, conversion, use|last= Wiser |first= Wendell H. |authorlink=  |year= 2000 |publisher= Birkhäuser |isbn= 978-0-387-98744-6 |page= 190 |url= http://books.google.com/books?id=UmMx9ixu90kC&pg=PA190&dq=electrical+power+generators+steam+percent&hl=en&ei=JppoTpVexNmBB4C72MkM&sa=X&oi=book_result&ct=result&resnum=2&ved=0CDgQ6AEwATgK#v=onepage&q=steam&f=false}}</ref>  The steam turbine is a form of [[heat engine]] that derives much of its improvement in [[thermodynamic efficiency]] from the use of multiple stages in the expansion of the steam, which results in a closer approach to the ideal reversible expansion process.
 
==History==
[[File:AEG marine steam turbine (Rankin Kennedy, Modern Engines, Vol VI).jpg|thumb|Diagram of an AEG marine steam turbine circa 1905]]
[[File:TMW 773 - Steam turbine generator set.jpg|thumb|A 250&nbsp;kW industrial steam turbine from 1910 (right) directly linked to a generator (left).]]
The first device that may be classified as a reaction steam turbine was little more than a toy, the classic [[Aeolipile]], described in the 1st century by [[Greek mathematics|Greek]] mathematician [[Hero of Alexandria]] in [[Roman Egypt]].<ref>turbine. Encyclopædia Britannica Online</ref><ref name="New look" >A new look at Heron's 'steam engine'" (1992-06-25). Archive for History of Exact Sciences 44 (2): 107-124.</ref><ref name="O'Connor, Heron" >O'Connor, J. J.; E. E. Roberston (1999). Heron of Alexandria. MacTutor</ref>  In 1551, [[Taqi al-Din Muhammad ibn Ma'ruf|Taqi al-Din]] in [[Ottoman Egypt]] described a steam turbine with the practical application of rotating a [[Spit (cooking aide)|spit]].  Steam turbines were also described by the Italian [[Giovanni Branca]] (1629)<ref>"''[http://books.google.com/books?id=Cv9LH4ckuEwC&pg=PA432&dq&hl=en#v=onepage&q=&f=false Power plant engineering]''". P. K. Nag (2002). [[Tata McGraw-Hill]]. p.432. ISBN 978-0-07-043599-5</ref> and [[John Wilkins]] in England (1648).<ref>[http://www.history-science-technology.com/Notes/Notes%201.htm Taqi al-Din and the First Steam Turbine, 1551 A.D.], web page, accessed on line October 23, 2009; this web page refers to [[Ahmad Y Hassan]] (1976), ''Taqi al-Din and Arabic Mechanical Engineering'', pp. 34-5, Institute for the History of Arabic Science, [[University of Aleppo]].</ref> The devices described by Taqi al-Din and Wilkins are today known as [[steam jack]]s.
 
The modern steam turbine was invented in 1884 by [[Charles Algernon Parsons|Sir Charles Parsons]], whose first model was connected to a [[dynamo]] that generated 7.5&nbsp;kW (10&nbsp;hp) of electricity.<ref name="birrcastle.com">[http://www.birrcastle.com/steamTurbineAndElectricity.asp ]{{dead link|date=September 2010}}</ref> The invention of Parsons' steam turbine made cheap and plentiful electricity possible and revolutionized marine transport and naval warfare.<ref>[http://www.universityscience.ie/pages/scientists/sci_charles_parsons.php ]{{dead link|date=September 2010}}</ref> Parsons' design was a [[#Reaction turbines|reaction]] type. His patent was licensed and the turbine scaled-up shortly after by an American, [[George Westinghouse]]. The Parsons turbine also turned out to be easy to scale up. Parsons had the satisfaction of seeing his invention adopted for all major world power stations, and the size of generators had increased from his first 7.5&nbsp;kW set up to units of 50,000&nbsp;kW capacity. Within Parson's lifetime, the generating capacity of a unit was scaled up by about 10,000 times,<ref name="Parsons, Steam Turbine" >{{cite web
|title=The Steam Turbine
|url=http://www.history.rochester.edu/steam/parsons/part1.html
|last=Parsons  |first=Sir Charles A.  |authorlink=Charles A. Parsons
}}</ref> and the total output from turbo-generators constructed by his firm [[C. A. Parsons and Company]] and by their licensees, for land purposes alone, had exceeded thirty million horse-power.<ref name="birrcastle.com"/>
 
A number of other variations of turbines have been developed that work effectively with steam. The ''de Laval turbine'' (invented by [[Gustaf de Laval]]) accelerated the steam to full speed before running it against a turbine blade.  De Laval's [[Steam_turbine#Impulse_turbines|impulse turbine]] is simpler, less expensive and does not need to be pressure-proof. It can operate with any pressure of steam, but is considerably less efficient.{{Citation needed|date=January 2013}}  [[:fr:Auguste Rateau]] developed a pressure compounded impulse turbine using the de Laval principle as early as 1900, obtained a US patent in 1903, and applied the turbine to a French torpedo boat in 1904.  He taught at the École des mines de Saint-Étienne for a decade until 1897, and later founded a successful company that was incorporated into the [[Alstom]] firm after his death.  One of the founders of the modern theory of steam and gas turbines was [[Aurel Stodola]], a Slovak physicist and engineer and professor at the Swiss Polytechnical Institute (now [[ETH]]) in Zurich. His work ''Die Dampfturbinen und ihre Aussichten als Wärmekraftmaschinen'' (English: The Steam Turbine and its prospective use as a Mechanical Engine) was published in Berlin in 1903. A further book ''Dampf und Gas-Turbinen'' (English: Steam and Gas Turbines) was published in 1922.
 
The ''Brown-Curtis turbine'', an [[#Impulse turbines|impulse]] type, which had been originally developed and patented by the U.S. company International Curtis Marine Turbine Company, was developed in the 1900s in conjunction with [[John Brown & Company]]. It was used in John Brown-engined merchant ships and warships, including liners and Royal Navy warships.
 
==Types==
Steam turbines are made in a variety of sizes ranging from small <0.75&nbsp;kW (<1&nbsp;hp) units (rare) used as mechanical drives for pumps, compressors and other shaft driven equipment, to 1,500,000&nbsp;kW (2,000,000&nbsp;hp) turbines used to generate electricity. There are several classifications for modern steam turbines.
 
===Blade and stage design===
[[File:Turbines impulse v reaction.png|thumb|250px|Schematic diagram outlining the difference between an impulse and a 50% reaction turbine]]
Turbine blades are of two basic types, blades and nozzles.  Blades move entirely due to the impact of steam on them and their profiles do not converge. This results in a steam velocity drop and essentially no pressure drop as steam moves through the blades. A turbine composed of blades alternating with fixed nozzles is called an [[#Impulse turbines|impulse turbine]], Curtis turbine, [[Pressure compounding in turbines|Rateau turbine]], or [[#History|Brown-Curtis turbine]]. Nozzles appear similar to blades, but their profiles converge near the exit. This results in a steam pressure drop and velocity increase as steam moves through the nozzles. Nozzles move due to both the impact of steam on them and the reaction due to the high-velocity steam at the exit. A turbine composed of moving nozzles alternating with fixed nozzles is called a [[#Reaction turbines|reaction turbine]] or [[#History|Parsons turbine]].
 
Except for low-power applications, turbine blades are arranged in multiple stages in series, called [[Compounding of steam turbines|compounding]], which greatly improves [[#Turbine efficiency|efficiency]] at low speeds.<ref>[https://en.wikisource.org/wiki/The_Steam_Turbine Parsons, Sir Charles A., "The Steam Turbine", p. 7-8]</ref> A reaction stage is a row of fixed nozzles followed by a row of moving nozzles. Multiple reaction stages divide the pressure drop between the steam inlet and exhaust into numerous small drops, resulting in a '''pressure-compounded''' turbine. Impulse stages may be either pressure-compounded, velocity-compounded, or pressure-velocity compounded. A pressure-compounded impulse stage is a row of fixed nozzles followed by a row of moving blades, with multiple stages for compounding. This is also known as a Rateau turbine, after its inventor. A '''velocity-compounded''' impulse stage (invented by Curtis and also called a "Curtis wheel") is a row of fixed nozzles followed by two or more rows of moving blades alternating with rows of fixed blades. This divides the velocity drop across the stage into several smaller drops.<ref>[https://en.wikisource.org/wiki/The_Steam_Turbine Parsons, Sir Charles A., "The Steam Turbine", p. 20-22]</ref> A series of velocity-compounded impulse stages is called a '''pressure-velocity compounded''' turbine.
 
By 1905, when steam turbines were coming into use on fast ships (such as [[HMS Dreadnought (1906)]]) and in land-based power applications, it had been determined that it was desirable to use one or more Curtis wheels at the beginning of a multi-stage turbine (where the steam pressure is highest), followed by reaction stages. This was more efficient with high-pressure steam due to reduced leakage between the turbine rotor and the casing.<ref>[https://en.wikisource.org/wiki/The_Steam_Turbine Parsons, Sir Charles A., "The Steam Turbine", p. 23-25]</ref> This is illustrated in the drawing of the German 1905 [[AEG]] marine steam turbine. The steam from the [[boiler]]s enters from the right at high pressure through a [[throttle]], controlled manually by an operator (in this case a [[sailor]] known as the throttleman). It passes through five Curtis wheels and numerous reaction stages (the small blades at the edges of the two large rotors in the middle) before exiting at low pressure, almost certainly to a [[surface condenser|condenser]]. The condenser provides a vacuum that maximizes the energy extracted from the steam, and condenses the steam into [[boiler feedwater|feedwater]] to be returned to the boilers. On the left are several additional reaction stages (on two large rotors) that rotate the turbine in reverse for astern operation, with steam admitted by a separate throttle. Since ships are rarely operated in reverse, efficiency is not a priority in astern turbines, so only a few stages are used to save cost.
 
===Steam supply and exhaust conditions===
[[File:BalNPP m st2.jpg|thumb|A low-pressure steam turbine working below atmospheric pressure in a nuclear power plant]]
These types include condensing, non-condensing, reheat, extraction and induction.
 
Condensing turbines are most commonly found in electrical power plants. These turbines exhaust steam from a [[boiler]] in a partially condensed state, typically of a [[steam quality|quality]] near 90%, at a pressure well below atmospheric to a [[surface condenser|condenser]].
 
Non-condensing or back pressure turbines are most widely used for process steam applications. The exhaust pressure is controlled by a regulating valve to suit the needs of the process steam pressure. These are commonly found at refineries, district heating units, pulp and paper plants, and [[desalination]] facilities where large amounts of low pressure process steam are needed.
 
Reheat turbines are also used almost exclusively in electrical power plants. In a reheat turbine, steam flow exits from a high pressure section of the turbine and is returned to the boiler where additional superheat is added. The steam then goes back into an intermediate pressure section of the turbine and continues its expansion. Using reheat in a cycle increases the work output from the turbine and also the expansion reaches conclusion before the steam condenses, there by minimizing the erosion of the blades in last rows. In most of the cases, maximum number of reheats employed in a cycle is 2 as the cost of super-heating the steam negates the increase in the work output from turbine.
 
Extracting type turbines are common in all applications. In an extracting type turbine, steam is released from various stages of the turbine, and used for industrial process needs or sent to boiler [[feed water heater]]s to improve overall cycle efficiency.  Extraction flows may be controlled with a valve, or left uncontrolled.
 
Induction turbines introduce low pressure steam at an intermediate stage to produce additional power.
 
===Casing or shaft arrangements===
These arrangements include single casing, tandem compound and cross compound turbines. Single casing units are the most basic style where a single casing and shaft are coupled to a generator. Tandem compound are used where two or more casings are directly coupled together to drive a single generator. A cross compound turbine arrangement features two or more shafts not in line driving two or more generators that often operate at different speeds. A cross compound turbine is typically used for many large applications.
 
===Two-flow rotors===
[[File:Turbine Philippsburg-1.jpg|thumb|A two-flow turbine rotor. The steam enters in the middle of the shaft, and exits at each end, balancing the axial force.]]
The moving steam imparts both a tangential and axial thrust on the turbine shaft, but the axial thrust in a simple turbine is unopposed. To maintain the correct rotor position and balancing, this force must be counteracted by an opposing force. Either [[thrust bearings]] can be used for the shaft bearings, or the rotor can be designed so that the steam enters in the middle of the shaft and exits at both ends. The blades in each half face opposite ways, so that the axial forces negate each other but the tangential forces act together. This design of rotor is called '''two-flow''', '''double-axial-flow''', or '''double-exhaust'''. This arrangement is common in low-pressure casings of a compound turbine.<ref name="phdengineer">{{cite web
| title = Steam Turbines (Course No. M-3006)
| url  = http://www.pdhengineer.com/Course%20Files/Completed%20Course%20PDF%20Files/Mechanical/Steam%20Turbines.pdf
| accessdate = 2011-09-22
| publisher = PhD Engineer
}}</ref>
 
==Principle of operation and design==
An ideal steam turbine is considered to be an [[isentropic process]], or constant entropy process, in which the entropy of the steam entering the turbine is equal to the entropy of the steam leaving the turbine. No steam turbine is truly isentropic, however, with typical isentropic efficiencies ranging from 20–90% based on the application of the turbine. The interior of a turbine comprises several sets of blades, or ''buckets'' as they are more commonly referred to. One set of stationary blades is connected to the casing and one set of rotating blades is connected to the shaft. The sets intermesh with certain minimum clearances, with the size and configuration of sets varying to efficiently exploit the expansion of steam at each stage.
 
=== Turbine efficiency===
To maximize turbine efficiency the steam is expanded, doing work, in a number of stages. These stages are characterized by how the energy is extracted from them and are known as either impulse or reaction turbines. Most steam turbines use a mixture of the reaction and impulse designs: each stage behaves as either one or the other, but the overall turbine uses both. Typically, higher pressure sections are reaction type and lower pressure stages are impulse type.
 
====Impulse turbines====
[[File:TurbineBlades.jpg|border|thumb|A selection of impulse turbine blades]]
An impulse turbine has fixed nozzles that orient the steam flow into high speed jets. These jets contain significant kinetic energy,  which is converted into shaft rotation by the bucket-like shaped rotor blades, as the steam jet changes direction. A pressure drop occurs across only the stationary blades, with a net increase in steam velocity across the stage.
As the steam flows through the nozzle its pressure falls from inlet pressure to the exit pressure (atmospheric pressure, or more usually, the condenser vacuum). Due to this high ratio of expansion of steam, the steam leaves the nozzle with a very high velocity. The steam leaving the moving blades has a large portion of the maximum velocity of the steam when leaving the nozzle. The loss of energy due to this higher exit velocity is commonly called the carry over velocity or leaving loss.
 
The law of [[angular momentum|moment of momentum]] states that the sum of the moments of external forces acting on a fluid which is temporarily occupying the [[control volume]] is equal to the net time change of angular momentum flux through the control volume.
 
The swirling fluid enters the control volume at radius <math>r_1</math> with tangential velocity <math>V_{w1}</math> and leaves at radius <math>r_2</math> with tangential velocity <math>V_{w2}</math>.
 
[[File:Edited blade design 1.png|border|alt = Velocity triangles at the inlet and outlet on the blades of a turbo-machine.|thumb|Velocity triangle]]
 
A [[velocity triangle]] paves the way for a better understanding of the relationship between the various velocities. In the adjacent figure we have:
:<math>V_1</math> and <math>V_2</math> are the absolute velocities at the inlet and outlet respectively.
:<math>V_{f1}</math> and <math>V_{f2}</math> are the flow velocities at the inlet and outlet respectively.
:<math>V_{w1} + U </math> and <math>V_{w2}</math> are the swirl velocities at the inlet and outlet respectively.
:<math>V_{r1}</math> and <math>V_{r2}</math> are the relative velocities at the inlet and outlet respectively.
:<math>U_1</math> and <math>U_2</math> are the velocities of the blade at the inlet and outlet respectively.
:<math>\alpha </math> is the guide vane angle and <math>\beta </math> is the blade angle.
 
Then by the law of moment of momentum, the torque on the fluid is given by:
 
<math>
T = \dot{m} ( r_2 V_{w2} - r_1 V_{w1} )
</math>
 
For an impulse steam turbine: <math> r_2 = r_1 = r</math>. Therefore, the tangential force on the blades is <math> F_u = \dot{m}(V_{w1}-V_{w2}) </math>. The work done per unit time or power developed: <math>{W} = {T*\omega}</math>.
 
When ω is the angular velocity of the turbine, then the blade speed is <math>{U} = {\omega*r}</math>. The power developed is then <math>W = \dot{m}U({\Delta }V_w)</math>.
 
'''Blade efficiency'''
 
Blade efficiency (<math>{\eta_b}</math>) can be defined as the ratio of the work done on the blades to kinetic energy supplied to the fluid, and is given by
 
<math>{\eta_b} = \frac{Work~Done}{Kinetic~Energy~Supplied} = \frac{2UV_w}{V_1^2}</math>
 
'''Stage efficiency'''
[[File:Edited cdn.png|thumb|right|Convergent-divergent nozzle]]
[[File:Edited efficiency impulse.png|thumb|right|Graph depicting efficiency of Impulse turbine]]
A stage of an impulse turbine consists of a nozzle set and a moving wheel. The stage efficiency defines a relationship between enthalpy drop in the nozzle and work done in the stage.
 
<math>{\eta_{stage}} = \frac{Work~done~on~blade}{Energy~supplied~per~stage} = \frac{U\Delta V_w}{\Delta h}</math>
 
Where <math>{\Delta h} = h_2-h_1 </math>  is the specific enthalpy drop of steam in the nozzle.
 
By the [[first law of thermodynamics]]: <math>{h_1} + \frac{V_1^2}{2} = {h_2} + \frac{V_2^2}{2}</math>
 
Assuming that <math>V_1</math> is appreciably less than <math>V_2</math>, we get <math>{\Delta h}</math> ≈ <math>\frac{V_2^2}{2}</math>
Furthermore, stage efficiency is the [[Product (mathematics)|product]] of blade efficiency and nozzle efficiency, or <math>{\eta_{stage}} = {\eta_b}*{\eta_N}</math>
 
Nozzle efficiency is given by <math>{\eta_N}</math> = <math>\frac{V_2^2}{2(h_1-h_2)}</math>, where the enthalpy (in J/Kg) of steam at the entrance of the nozzle is <math> h_1 </math> and the enthalpy of steam at the exit of the nozzle is <math> h_2 </math>.
<math>{\Delta V_w} = V_{w1}-(-V_{w2})</math>
<math>{\Delta V_w} = V_{w1}+V_{w2}</math>
<math>{\Delta V_w} = {V_{r1}\cos \beta_1+V_{r2}\cos \beta_2}</math>
<math>{\Delta V_w} = {V_{r1}\cos \beta_1}(1+\frac{V_{r2}\cos \beta_2}{V_{r1}\cos \beta_1})</math>
 
The ratio of the cosines of the blade angles at the outlet and inlet can be taken and denoted <math>{c} = \frac{\cos \beta_2}{\cos \beta_1}</math>.
The ratio of steam velocities relative to the rotor speed at the outlet to the inlet of the blade is defined by the friction coefficient <math>{k} = \frac{V_{r2}}{V_{r1}}</math>.
 
<math>k < 1</math> and depicts the loss in the relative velocity due to friction as the steam flows around the blades (<math>k = 1</math> for smooth blades).
 
<math>{\eta_b} = \frac{2 U \Delta V_w}{V_1^2} = \frac{2 U(\cos \alpha_1-U/V_1)(1+kc)}{V_1}</math>
 
The ratio of the blade speed to the absolute steam velocity at the inlet is termed the blade speed ratio <math>{\rho}</math> =  <math>\frac{U}{V_1}</math>
 
<math>{\eta_b}</math> is maximum when <math>{d\eta_b\over d\rho} = 0 </math> or, <math>\frac{d}{d\rho}(2{\cos \alpha_1-\rho^2 }(1+kc)) = 0 </math>. That implies <math>{\rho} = \frac{\cos \alpha_1}{2}</math> and therefore <math>\frac{U}{V_1} = \frac{\cos \alpha_1}{2}</math>. Now <math>{\rho_{opt}} = \frac{U}{V_1} = \frac{\cos \alpha_1}{2}</math> (for a single stage impulse turbine)
 
Therefore the maximum value of stage efficiency is obtained by putting the value of <math>\frac{U}{V_1} = \frac{\cos \alpha_1}{2}</math> in the expression of <math>{\eta_b}</math>/
 
We get: <math>{(\eta_b)_{max}} = 2(\rho\cos\alpha_1-\rho^2)(1+kc) = \frac{\cos^2\alpha_1 (1+kc)}{2}</math>.
 
For equiangular blades, <math>\beta_1  = \beta_2 </math>, therefore <math>c = 1</math>, and we get <math>{(\eta_b)_{max}} = \frac{cos^2\alpha_1(1+k)}{2}</math>. If the friction due to the blade surface is neglected then <math>{(\eta_b)_{max}} = {\cos^2\alpha_1}</math>.
 
'''Conclusions on maximum efficiency'''
 
<math>{(\eta_b)_{max}} = {\cos^2\alpha_1}</math>
 
1. For a given steam velocity work done per kg of steam would be maximum when <math>{\cos^2\alpha_1} = 1 </math> or <math>\alpha_1 = 0 </math>.
 
2. As <math>\alpha_1 </math> increases, the work done on the blades reduces, but at the same time surface area of the blade reduces, therefore there are less frictional losses.
 
====Reaction turbines====
 
In the ''reaction turbine'', the [[Rotor (turbine)|rotor]] blades themselves are arranged to form convergent [[nozzle]]s. This type of turbine makes use of the reaction force produced as the steam accelerates through the nozzles formed by the rotor. Steam is directed onto the rotor by the fixed vanes of the [[stator]]. It leaves the stator as a jet that fills the entire circumference of the rotor. The steam then changes direction and increases its speed relative to the speed of the blades. A pressure drop occurs across both the stator and the rotor, with steam accelerating through the stator and decelerating through the rotor, with no net change in steam velocity across the stage but with a decrease in both pressure and temperature, reflecting the work performed in the driving of the rotor.
 
'''Blade efficiency'''
 
Energy input to the blades in a stage:
 
<math>E = {\Delta h}</math> is equal to the kinetic energy supplied to the fixed blades (f) + the kinetic energy supplied to the moving blades (m).
 
Or, <math>{E}</math> = enthalpy drop over the fixed blades, <math>{\Delta h_f}</math> + enthalpy drop over the moving blades, <math>{\Delta h_m}</math>.
 
The effect of expansion of steam over the moving blades is to increase the relative velocity at the exit. Therefore the relative velocity at the exit <math>V_{r2}</math> is always greater than the relative velocity at the inlet <math>V_{r1}</math>.
 
In terms of velocities, the enthalpy drop over the moving blades is given by:
 
<math>{\Delta h_m} = \frac{V_{r2}^2 - V_{r1}^2}{2}</math> 
(it contributes to a change in static pressure)
 
The enthalpy drop in the fixed blades, with the assumption that the velocity of steam entering the fixed blades is equal to the velocity of steam leaving the previously moving blades is given by:
 
[[File:Edited blade design.png|thumb|right|450px|Velocity diagram]]
 
<math>{\Delta h_f}</math> =  <math>\frac{V_1^2 - V_0^2}{2}</math>  where V<sub>0</sub> is the inlet velocity of steam in the nozzle
 
<math>V_{0}</math> is very small and hence can be neglected
 
Therefore, <math>{\Delta h_f}</math> =  <math>\frac{V_1^2}{2}</math>
 
<math>E = {\Delta h_f+\Delta h_m}</math>
 
<math>E = \frac{V_1^2}{2} + \frac{V_{r2}^2 - V_{r1}^2}{2}</math>
 
A very widely used design has half [[degree of reaction]] or 50% reaction and this is known as '''Parson’s turbine'''. This consists of symmetrical rotor and stator blades.
For this turbine the velocity triangle is similar and we have:
 
<math>\alpha_1  = \beta_2 </math>,  <math>\beta_1  = \alpha_2 </math>
 
<math>V_1 = V_{r2}</math>,  <math>V_{r1} = V_2</math>
 
Assuming ''Parson’s turbine'' and obtaining all the expressions we get
 
<math>{E} = {V_1^2}-\frac{V_{r1}^2}{2}</math>
 
From the inlet velocity triangle we have <math>{V_{r1}^2} = {V_1^2-U^2-2UV_1\cos\alpha_1}</math>
 
<math>{E} = {V_1^2-\frac{V_1^2}{2}-\frac{U^2}{2}+\frac{2UV_1\cos\alpha_1}{2}}</math>
 
<math>{E} = \frac{V_1^2-U^2+2UV_1\cos\alpha_1}{2}</math>
 
Work done (for unit mass flow per second): <math>{W} = {U * \Delta V_w} = {U*(2*V_1\cos\alpha_1-U)}</math>
 
Therefore the '''blade efficiency''' is given by
 
<math>{\eta_b} = \frac{2U(2V_1\cos\alpha_1-U)}{V_1^2-U^2+2V_1U\cos\alpha_1}</math>
 
'''Condition of maximum blade efficiency'''
 
[[File:Edited comparing efficiencies.png|thumb|right|400px| Comparing Efficiencies of Impulse and Reaction turbines]]
 
If <math>{\rho} = \frac{U}{V_1}</math>, then
 
<math>{(\eta_b)_{max}} = \frac{2\rho(\cos\alpha_1-\rho)}{V_1^2-U^2+2UV_1\cos\alpha_1}</math>
 
For maximum efficiency  <math>{d\eta_b\over d\rho} = 0</math>, we get
 
<math>{(1-\rho^2+2\rho\cos \alpha_1)(4\cos \alpha_1-4\rho) -2\rho(2\cos \alpha_1- \rho)(-2\rho+2\cos \alpha_1) = 0}</math>
 
and this finally gives <math>{\rho_{opt}} = \frac{U}{V_1} = {\cos \alpha_1}</math>
 
Therefore <math>{(\eta_b)_{max}}</math> is found by putting the value of <math>{\rho} =  {\cos \alpha_1}</math> in the expression of blade efficiency
 
<math>{(\eta_b)_{reaction}} = \frac{2\cos^2\alpha_1}{1+\cos^2\alpha_1}</math>
 
<math>{(\eta_b)_{impulse}} = {\cos^2\alpha_1}</math>
 
===Operation and maintenance===
[[File:Modern Steam Turbine Generator.jpg|thumb|A modern steam turbine generator installation]]
 
Because of the high pressures used in the steam circuits and the materials used, steam turbines and their casings have high [[Volumetric heat capacity#Thermal_inertia|thermal inertia]]. When warming up a steam turbine for use, the main steam stop valves (after the boiler) have a bypass line to allow superheated steam to slowly bypass the valve and proceed to heat up the lines in the system along with the steam turbine.  Also, a [[turning gear]] is engaged when there is no steam to slowly rotate the turbine to ensure even heating to prevent [[Thermal shock|uneven expansion]].  After first rotating the turbine by the turning gear, allowing time for the rotor to assume a straight plane (no bowing), then the turning gear is disengaged and  steam is admitted to the turbine, first to the astern blades then to the ahead blades slowly rotating the turbine at 10–15&nbsp;RPM (0.17–0.25&nbsp;Hz) to slowly warm the turbine. The warm up procedure for large steam turbines may exceed ten hours.<ref name=EEA_EPA_report/>
 
During normal operation, rotor imbalance can lead to vibration, which, because of the high rotation velocities, could lead to a blade breaking away from the rotor and through the casing. To reduce this risk, considerable efforts are spent to balance the turbine. Also, turbines are run with high quality steam: either [[Superheated steam|superheated (dry) steam]], or saturated steam with a high dryness fraction. This prevents the rapid impingement and erosion of the blades which occurs when condensed water is blasted onto the blades (moisture carry over).  Also, liquid water entering the blades may damage the thrust bearings for the turbine shaft.  To prevent this, along with controls and baffles in the boilers to ensure high quality steam, condensate drains are installed in the steam piping leading to the turbine.
 
Maintenance requirements of modern steam turbines are simple and incur low costs (typically around $0.005 per kWh);<ref name=EEA_EPA_report>{{cite web|last=Energy and Environmental Analysis|title=Technology Characterization: Steam Turbines (2008)|url=http://www.epa.gov/chp/documents/catalog_chptech_steam_turbines.pdf|work=Report prepared for U.S. Environmental Protection Agency|accessdate=25 February 2013|page=13|format=PDF|year=2008}}</ref>  their operational life often exceeds 50 years.<ref name=EEA_EPA_report/>
 
===Speed regulation===
[[File:Turbine generator systems1.png|thumbnail|300px|Diagram of a steam turbine generator system]]
The control of a turbine with a governor is essential, as turbines need to be run up slowly to prevent damage and some applications (such as the generation of alternating current electricity) require precise speed control.<ref>{{cite book|last=Whitaker|first=Jerry C. |title=AC power systems handbook|publisher=Taylor and Francis|location=Boca Raton, FL|year=2006|page=35|isbn=978-0-8493-4034-5}}</ref> Uncontrolled acceleration of the turbine rotor can lead to an overspeed trip, which causes the nozzle valves that control the flow of steam to the turbine to close. If this fails then the turbine may continue accelerating until it breaks apart, often catastrophically. Turbines are expensive to make, requiring precision manufacture and special quality materials.
 
During normal operation in synchronization with the electricity network, power plants are governed with a five percent [[droop speed control]]. This  means the full load speed is 100% and the no-load speed is 105%. This is required for the stable operation of the network without hunting and drop-outs of power plants. Normally the changes in speed are  minor. Adjustments in power output are made by slowly raising the droop curve by increasing the spring pressure on a [[centrifugal governor]]. Generally this is a  basic system requirement for all power plants because  the older and newer plants have to be compatible in response to the instantaneous changes in frequency without depending on outside communication.<ref>Speed Droop and Power Generation. Application Note 01302. 2. Woodward. Speed</ref>
 
===Thermodynamics of steam turbines===
[[File:Rankine cycle with superheat.jpg|thumbnail|300px|T-s diagram of a superheated [[Rankine cycle]]]]
The steam turbine operates on basic principles of [[thermodynamics]] using the part 3-4 of the [[Rankine cycle]] shown in the adjoining diagram. [[Superheated]] vapor (or dry saturated vapor, depending on application) enters the turbine, after it having exited the boiler, at high temperature and high pressure. The high heat/pressure steam is converted into kinetic energy using a nozzle (a fixed nozzle in an impulse type turbine or the fixed blades in a reaction type turbine). Once the steam has exited the nozzle it is moving at high velocity and is sent to the blades of the turbine. A force is created on the blades due to the pressure of the vapor on the blades causing them to move. A generator or other such device can be placed on the shaft, and the energy that was in the vapor can now be stored and used. The gas exits the turbine as a saturated vapor (or liquid-vapor mix depending on application) at a lower temperature and pressure than it entered with and is sent to the condenser to be cooled.<ref>Roymech, http://www.roymech.co.uk/Related/Thermos/Thermos_Steam_Turbine.html</ref> If we look at the first law we can find an equation comparing the rate at which work is developed per unit mass. Assuming there is no heat transfer to the surrounding environment and that the change in kinetic and potential energy is negligible when compared to the change in specific [[enthalpy]] we come up with the following equation
: <math> \frac {\dot{W}}{\dot{m}}=h_3-h_4 </math>
 
where
* '''Ẇ''' is the rate at which work is developed per unit time
* '''ṁ''' is the rate of mass flow through the turbine
 
====Isentropic turbine efficiency====
To measure how well a turbine is performing we can look at its [[isentropic]] efficiency. This compares the actual performance of the turbine with the performance that would be achieved by an ideal, isentropic, turbine.<ref name="ReferenceA">"Fundamentals of Engineering Thermodynamics" Moran and Shapiro, Published by Wiley</ref>  When calculating this efficiency, heat lost to the surroundings is assumed to be zero. The starting pressure and temperature is the same for both the actual and the ideal turbines, but at turbine exit the energy content ('specific enthalpy') for the actual turbine is greater than that for the ideal turbine because of irreversibility in the actual turbine. The specific enthalpy is evaluated at the same pressure for the actual and ideal turbines in order to give a good comparison between the two.
 
The isentropic efficiency is found by dividing the actual work by the ideal work.<ref name="ReferenceA"/>
: <math>\eta_t = \frac {h_3-h_4}{h_3-h_{4s}} </math>
 
where
* '''''h<sub>3</sub>''''' is the specific enthalpy at state three
* '''''h<sub>4</sub>''''' is the specific enthalpy at state four for the actual turbine
* '''''h<sub>4s</sub>''''' is the specific enthalpy at state four for the isentropic turbine
 
==Direct drive==
[[File:Dampfturbine 5 MW mit ELIN Generator.jpg|thumb|A direct-drive 5 MW steam turbine fueled with biomass]]
[[electricity generation|Electrical power stations]] use large steam turbines driving [[electric generator]]s to produce most (about 80%) of the world's electricity. The advent of large steam turbines made central-station electricity generation practical, since reciprocating steam engines of large rating became very bulky, and operated at slow speeds.  Most central stations are [[fossil fuel power plant]]s and [[nuclear power plant]]s; some installations use [[geothermal]] steam, or use [[concentrated solar power]] (CSP) to create the steam.  Steam turbines can also be used directly to drive large [[centrifugal pump]]s, such as [[feedwater pump]]s at a [[thermal power plant]].
 
The turbines used for electric power generation are most often directly coupled to their generators.  As the generators must rotate at constant synchronous speeds according to the frequency of the electric power system, the most common speeds are 3,000&nbsp;RPM for 50&nbsp;Hz systems, and 3,600&nbsp;RPM for 60&nbsp;Hz systems.  Since nuclear reactors have lower temperature limits than fossil-fired plants, with lower steam [[Vapor quality|quality]], the turbine generator sets may be arranged to operate at half these speeds, but with four-pole generators, to reduce erosion of turbine blades.<ref>
{{cite book
| last = Leyzerovich
| first = Alexander
| authorlink =
| coauthors =
| title = Wet-steam Turbines for Nuclear Power Plants
| publisher = PennWell Books
| year = 2005
| location = Tulsa OK
| page = 111
| url =
| doi =
| id =
| isbn = 978-1-59370-032-4
}}</ref>
 
==Marine propulsion==
{{Redirect2|TSS|Turbine Steam Ship}}
[[File:Turbinia At Speed.jpg|thumb|right|The ''[[Turbinia]]'', 1894, the first steam turbine-powered ship]]
[[File:Wirnik turbiny parowej ORP Wicher.jpg|thumb|Parsons turbine from the 1928 Polish destroyer [[ORP Wicher (1958)|ORP ''Wicher'']].]]
In steam-powered ships, compelling advantages of steam turbines over reciprocating engines are smaller size, lower maintenance, lighter weight, and lower vibration. A steam turbine is only efficient when operating in the thousands of RPM, while the most effective propeller designs are for speeds less than 300 RPM; consequently, precise (thus expensive) reduction gears are usually required, although numerous early ships through [[World War I]], such as ''[[Turbinia]]'', had direct drive from the steam turbines to the propeller shafts. Another alternative is [[turbo-electric transmission]], in which an electrical generator run by the high-speed turbine is used to run one or more slow-speed electric motors connected to the propeller shafts; precision gear cutting may be a production bottleneck during wartime.  Turbo-electric drive was most used in large US warships designed during World War I and in some fast liners, and was used in some troop transports and mass-production [[Buckley-class destroyer escort|destroyer escorts]] in [[World War II]]. The purchase cost of turbines is offset by much lower fuel and maintenance requirements and the small size of a turbine when compared to a reciprocating engine having an equivalent power. However, from the 1950s diesel engines were capable of greater reliability and higher efficiencies: propulsion steam turbine cycle efficiencies have yet to break 50%, yet diesel engines today routinely exceed 50%, especially in marine applications.<ref>{{cite web |url= http://ansys.com/assets/testimonials/siemens.pdf |title=MCC CFXUpdate23 LO A/W.qxd |format=PDF |date= |accessdate=2010-09-12}}</ref><ref>{{cite web |url= http://pepei.pennnet.com/display_article/152601/6/ARTCL/none/none/1/New-Benchmarks-for-Steam-Turbine-Efficiency/ |title=New Benchmarks for Steam Turbine Efficiency - Power Engineering |publisher=Pepei.pennnet.com |date= |accessdate=2010-09-12|archiveurl = http://www.webcitation.org/5uL1DFU6x |archivedate = 2010-11-18|deadurl=no}}</ref><ref>https://www.mhi.co.jp/technology/review/pdf/e451/e451021.pdf</ref> Diesel power plants also have lower operating costs since fewer operators are required. Thus, conventional steam power is used in very few new ships.
 
[[Nuclear marine propulsion|Nuclear-powered ships and submarines]] use a nuclear reactor to create steam for turbines.  Nuclear power is often chosen where diesel power would be impractical (as in [[submarine]] applications) or the logistics of refuelling pose significant problems (for example, [[icebreaker]]s). It has been estimated that the reactor fuel for the [[Royal Navy]]'s [[Vanguard class submarine]] is sufficient to last 40 circumnavigations of the globe – potentially sufficient for the vessel's entire service life. Nuclear propulsion has only been applied to a very few commercial vessels due to the expense of maintenance and the regulatory controls required on nuclear systems and fuel cycles.
 
===Early development===
 
The development of steam turbine marine propulsion from 1894-1935 was dominated by the need to reconcile the high efficient speed of the turbine with the low efficient speed (less than 300 rpm) of the ship's propeller at an overall cost competitive with [[marine steam engine|reciprocating engines]]. In 1894, efficient reduction [[gear]]s were not available for the high powers required by ships, so [[direct drive]] was necessary. In the ''[[Turbinia]]'', which has direct drive to each propeller shaft, the efficient speed of the turbine was reduced after initial trials by directing the steam flow through all three direct drive turbines (one on each shaft) in series, probably totaling around 200 turbine stages operating in series. Also, there were three propellers on each shaft for operation at high speeds.<ref>[https://en.wikisource.org/wiki/The_Steam_Turbine Parsons, Sir Charles A., "The Steam Turbine", p. 26-31]</ref> The high shaft speeds of the era are represented by one of the first US turbine-powered [[destroyer]]s, [[USS Smith (DD-17)]], launched in 1909, which had direct drive turbines and whose three shafts turned at 724 rpm at 28.35 knots.<ref>Friedman, Norman, "US Destroyers, an Illustrated Design History, Revised Edition, Naval Institute Press, Annapolis: 2004, p. 23-24.</ref> The use of turbines in several casings exhausting steam to each other in series became standard in most subsequent marine propulsion applications, and is a form of [[#Types|cross-compounding]]. The first turbine was called the high pressure (HP) turbine, the last turbine was the low pressure (LP) turbine, and any turbine in between was an intermediate pressure (IP) turbine. A much later arrangement than ''Turbinia'' can be seen on the [[RMS Queen Mary]] in [[Long Beach, California]], launched in 1934, in which each shaft is powered by four turbines in series connected to the ends of the two input shafts of a single-reduction gearbox. They are the HP, 1st IP, 2nd IP, and LP turbines.
 
===Cruising machinery and gearing===
 
The quest for economy was even more important when cruising speeds were considered. Cruising speed is roughly 50% of a warship's maximum speed and 20-25% of its maximum power level.  This would be a speed used on long voyages when fuel economy is desired. Although this brought the propeller speeds down to an efficient range, turbine efficiency was greatly reduced, and early turbine ships had poor cruising ranges. A solution that proved useful through most of the steam turbine propulsion era was the cruising turbine. This was an extra turbine to add even more stages, at first attached directly to one or more shafts, exhausting to a stage partway along the HP turbine, and not used at high speeds. As reduction gears became available around 1911, some ships, notably the [[USS Nevada (BB-36)]], had them on cruising turbines while retaining direct drive main turbines. Reduction gears allowed turbines to operate in their efficient range at a much higher speed than the shaft, but were expensive to manufacture.
 
Cruising turbines competed at first with reciprocating engines for fuel economy. An example of the retention of reciprocating engines on fast ships was the famous [[RMS Titanic]] of 1911, which along with her sisters [[RMS Olympic]] and [[HMHS Britannic]] had triple-expansion engines on the two outboard shafts, both exhausting to an LP turbine on the center shaft. After adopting turbines with the [[Delaware-class battleship]]s launched in 1909, the [[United States Navy]] reverted to reciprocating machinery on the [[New York-class battleship]]s of 1912, then went back to turbines on ''Nevada'' in 1914. The lingering fondness for reciprocating machinery was because the US Navy had no plans for capital ships exceeding 21 knots until after World War I, so top speed was less important than economical cruising. The United States had acquired the [[Philippines]] and [[Hawaii]] as territories in 1898, and lacked the British [[Royal Navy]]'s worldwide network of [[coaling station]]s. Thus, the US Navy in 1900-1940 had the greatest need of any nation for fuel economy, especially as the prospect of war with [[Japan]] arose following World War I. This need was compounded by the US not launching any cruisers 1908-1920, so destroyers were required to perform long-range missions usually assigned to cruisers. So, various cruising solutions were fitted on US destroyers launched 1908-1916. These included small reciprocating engines and geared or ungeared cruising turbines on one or two shafts. However, once fully geared turbines proved economical in initial cost and fuel they were rapidly adopted, with cruising turbines also included on most ships. Beginning in 1915 all new Royal Navy destroyers had fully geared turbines, and the United States followed in 1917.
 
In the [[Royal Navy]], speed was a priority until the [[Battle of Jutland]] in mid-1916 showed that in the [[battlecruiser]]s too much armour had been sacrificed in its pursuit. The British used exclusively turbine-powered warships from 1906. Because they recognized that a significant cruising range would be desirable given their world-wide empire, some warships, notably the [[Queen Elizabeth-class battleship]]s, were fitted with cruising turbines from 1912 onwards following earlier experimental installations.
 
In the US Navy, the [[Mahan-class destroyer]]s, launched 1935-36, introduced double-reduction gearing. This further increased the turbine speed above the shaft speed, allowing smaller turbines than single-reduction gearing. Steam pressures and temperatures were also increasing progressively, from 300 psi/425 F (2.07 MPa/218 C)([[saturation temperature]]) on the World War I-era [[Wickes-class destroyer|Wickes class]] to 615 psi/850 F (4.25 MPa/454 C) [[superheated steam]] on some World War II [[Fletcher-class destroyer]]s and later ships.<ref>[http://destroyerhistory.org/goldplater/1500ton Destroyer History Foundation, "1,500 tonner" web page]</ref><ref>Friedman, p. 472</ref> A standard configuration emerged of an axial-flow high pressure turbine (sometimes with a cruising turbine attached) and a double-axial-flow low pressure turbine connected to a double-reduction gearbox. This arrangement continued throughout the steam era in the US Navy and was also used in some Royal Navy designs.<ref>[http://www.hazegray.org/navhist/canada/systems/propulsion/y100/y100.pdf Bowie, David, "Cruising Turbines of the Y-100 Naval Propulsion Machinery"]</ref><ref>[http://www.leander-project.homecall.co.uk/turbines.html The Leander Project turbine page]</ref> Machinery of this configuration can be seen on many preserved World War II-era warships in several countries.<ref>[http://www.hnsa.org/index.htm Historic Naval Ships Association website]</ref> When US Navy warship construction resumed in the early 1950s, most surface combatants and aircraft carriers used 1,200 psi/950 F (8.28 MPa/510 C) steam.<ref>Friedman, p. 477</ref> This continued until the end of the US Navy steam-powered warship era with the [[Knox-class frigate]]s of the early 1970s. Amphibious and auxiliary ships continued to use 600 psi (4.14 MPa) steam post-World War II, with the [[USS Iwo Jima (LHD-7)]], launched in 2001, possibly being the last non-nuclear steam-powered ship built for the US Navy. Except for [[nuclear marine propulsion|nuclear-powered ships and submarines]], steam turbines have been replaced by [[gas turbine]]s on fast ships and by [[diesel engine]]s on other ships.
 
===Turbo-electric drive===
[[File:50letPob pole.JPG|thumb|The [[50 Let Pobedy]] nuclear icebreaker with nuclear-turbo-electric propulsion]]
[[Turbo-electric transmission|Turbo-electric drive]] was introduced on the [[USS New Mexico (BB-40)]], launched in 1917. Over the next eight years the US Navy launched five additional turbo-electric-powered battleships and two aircraft carriers (initially ordered as [[Lexington-class battlecruiser]]s). Ten more turbo-electric capital ships were planned, but cancelled due to the limits imposed by the [[Washington Naval Treaty]]. Although ''New Mexico'' was refitted with geared turbines in a 1931-33 refit, the remaining turbo-electric ships retained the system throughout their careers. This system used two large steam turbine generators to drive an electric motor on each of four shafts. The system was less costly initially than reduction gears and made the ships more maneuverable in port, with the shafts able to reverse rapidly and deliver more reverse power than with most geared systems. Some ocean liners were also built with turbo-electric drive, as were some troop transports and mass-production [[Buckley-class destroyer escort|destroyer escorts]] in [[World War II]]. However, when the US designed the "treaty cruisers", beginning with the [[USS Pensacola (CA-24)]] launched in 1927, geared turbines were used for all fast steam-powered ships thereafter.
 
==Locomotives==
{{Main|Steam turbine locomotive}}
A steam turbine locomotive engine is a [[steam locomotive]] driven by a steam turbine.
 
The main advantages of a steam turbine locomotive are better rotational balance and reduced [[hammer blow]] on the track. However, a disadvantage is less flexible power output power so that turbine locomotives were best suited for long-haul operations at a constant output power.<ref name=Streeter>Streeter, Tony: 'Testing the Limit' (''Steam Railway Magazine'': 2007, 336), pp. 85</ref>
 
The first steam turbine rail locomotive was built in 1908 for the Officine Meccaniche Miani Silvestri Grodona Comi, Milan, Italy. In 1924 [[Krupp]] built the steam turbine locomotive T18 001, operational in 1929, for [[Deutsche Reichsbahn]].
 
==Testing==
British, German, other national and international test codes are used to standardize the procedures and definitions used to test steam turbines. Selection of the test code to be used is an agreement between the purchaser and the manufacturer, and has some significance to the design of the turbine and associated systems. In the United States, [[ASME]] has produced several performance test codes on steam turbines. These include ASME PTC 6-2004, Steam Turbines, ASME PTC 6.2-2011, Steam Turbines in [[Combined cycle|Combined Cycles]], PTC 6S-1988, Procedures for Routine Performance Test of Steam Turbines. These ASME performance test codes have gained international recognition and acceptance for testing steam turbines. The single most important and differentiating characteristic of ASME performance test codes, including PTC 6, is that the test uncertainty of the measurement indicates the quality of the test and is not to be used as a commercial tolerance.<ref>William P. Sanders (ed), ''Turbine Steam Path Mechanical Design and Manufacture, Volume Iiia''
(PennWell Books, 2004) ISBN 1-59370-009-1 page 292</ref>
 
==See also==
* [[Balancing machine]]
* [[Mercury vapour turbine]]
* [[Tesla turbine]]
* [[Turbine]]
* [[:fr:Auguste Rateau]], steam and combustion-engine turbine developer
 
==References==
{{reflist}}
 
==Further reading==
* {{cite book
|title=Evaluating and Improving Steam Turbine Performance
|last=Cotton  |first=K.C.
|year=1998
|ref=Cotton
}}
* {{cite book
|title=[[s:The Steam Turbine|The Steam Turbine]]
|last=Parsons | first=Charles A.
|authorlink=Charles Algernon Parsons
|publisher=University Press, Cambridge
|year=1911}}
* {{cite book
|title=Thermische Turbomaschinen
|last=Traupel  |first=W.
|year=1977
|language=German
|ref=Traupel, Thermische Turbomaschinen
}}
* {{cite book
|title=A History of the Growth of the Steam Engine''
|last=Thurston  |first=R. H.
|publisher=D. Appleton and Co.
|year=1878
|ref=Thurston
}}
 
==External links==
{{Commons category|Steam turbines}}
* ''[[gutenberg:27687|Steam Turbines: A Book of Instruction for the Adjustment and Operation of the Principal Types of this Class of Prime Movers]]'' by Hubert E. Collins
* [http://www.engwonders.byethost9.com/e074.html Steam Turbine Construction at Mike's Engineering Wonders]
* [http://www.spiraxsarco.com/resources/steam-engineering-tutorials/steam-engineering-principles-and-heat-transfer/superheated-steam.asp Tutorial: "Superheated Steam" ]
* [http://www.softinway.com/news/articles/Steam-turbine-disk-stator-cavities-1.asp Flow Phenomenon in Steam Turbine Disk-Stator Cavities Channeled by Balance Holes]
* [http://www.aqpl43.dsl.pipex.com/MUSEUM/LOCOLOCO/locoloco.htm Extreme Steam- Unusual Variations on The Steam Locomotive]
* [http://www.powerplant.vissim.com Interactive Simulation] of 350MW Steam Turbine with Boiler developed by [[The University of Queensland]], in Brisbane Australia
* [http://books.google.com/books?id=79oDAAAAMBAJ&pg=PA236&dq=Popular+Science+1933+plane+%22Popular+Mechanics%22&hl=en&ei=RasMTuyGFYifsQLC3sGzCg&sa=X&oi=book_result&ct=result&resnum=2&ved=0CC0Q6AEwATgK#v=onepage&q&f=true "Super-Steam...An Amazing Story of Achievement"] ''Popular Mechanics'', August 1937
 
{{Heat engines}}
 
{{DEFAULTSORT:Steam Turbine}}
[[Category:Turbines]]
[[Category:Steam engines|Turbine]]
[[Category:English inventions]]
[[Category:History of the steam engine|Turbine]]
[[Category:Steam turbines]]
[[Category:1884 introductions]]

Revision as of 02:11, 25 February 2014

Marvella is what you can contact her but it's not the most feminine title out there. She is a librarian but she's always needed her personal company. His wife doesn't like it the way he does but what he really likes performing is to do aerobics and he's been performing it for fairly a while. Her family life in Minnesota.

My homepage std testing at home